Coaxial Cable Driver & Matching Amplifiers

coaxial.jpg

FIBER OPTIC TRANSMISSION ALSO AVAILABLE

  • Wideband: DC to over 30MHz

  • Maximum Output: to 10V PK, 20V PK-PK

  • Maximum Input: ±5V to ±200V PK-PK as required. Also to 900kV PK with Ross Voltage Divider

  • Signal Isolation: 500,000 Ohm 450V PK

  • Input Impedance: Up to 2 Megohms

  • Load Impedance: 50 Ohm or greater

  • Power Source: AC or Optional Battery

  • Will drive over 500 Feet of Coaxial Cable

Matching Amplifier
Model VDE-
Wideband: DC to over 30MHz

  • Signal Input

    • 0 to ±50 volt peak differential.

    • (0-100V PK-PK) standard. Other available.

    • Peak common mode voltage that will not damage amplifier or distort the output.

      • 200 volt steady state

      • 450 volt transient

    • Impedance

      • 1.0 megohm in parallel with 10pF or 2.0 meghom in parallel with 15pF as ordered. 

  • Signal Output

    • 0 to ±10 volts (20 volts PK-PK) into 50 ohm or greater load.

    • ±200mA. Peak Maximum load current.

    • Matching amplifier isolation of signal output from signal input is 500 kilohm in parallel with 20pF.

    • Gain / frequency. See figure #1 below

    • Undistorted output voltage swing. See figure #2 below

    • Square wave input. Rise and fall time<10ns.

    • Matching amplifier output is calibrated into a specified length of cable and a 50 ohm or greater load as specified by the customer.

  • Power Requirements

    • 105V to 125V AC, 50/60Hz.

    • Power Consumption-5W.

  • Environmental

    • Indoor.

    • 0 °C to +50 °C.

  • Dimensions

    • 3 1/2” high x 7” wide x 8 3/8” deep.

  • Miscellaneous

    • Red LED indicates power on.

    • Model VDE-Matching Amplifier includes cabinet, amplifier, 115 volt 50-400Hz power supply, cable and terminations as specified by the customer.

    • Power supply input isolated for 2000 volts.

    • Matching amplifier may also be used with other test equipment such as voltmeters, signal generators, recorders, etc.

  • WARNING

    • MATCHING AMPLIFIER OUTPUT COAXIAL CABLE SHIELD IS NOTGROUNDED. FOR SAFETY, OUTPUT COAXIAL CABLE SHIELD SHOULD BE GROUNDED AT COAXIAL CABLE TERMINATING RESISTOR.

    • If output coaxial cable is connected to matching amplifier input ground or matching amplifier 115 volt ground, there may be excessive ground currents causing electrical noise in matching amplifier output.

  • CAUTION

    • Do not subject output to reverse voltage.

    • External pickup from coaxial cables can easily exceed safe values if the cables are run near high pulse current conductors.

    • The matching amplifier, coaxial cable and coaxial cable terminating resistor are calibrated as a system.

    • If any of these are changed, the calibration, the high frequency response and the pulse response may change.

  • Options On Request

    • Signal Input Variations Available:

      • Any maximum input voltage from ±0.5 to over ±250 volt with proper input range selected, to over 900kV when using Ross Engineering Corp. voltage dividers.

    • Signal Output Variations Available:

      • Coaxial cable lengths from 0 to 500 feet

    • Power Options Available:

      • Battery or DC operated. 115V, 208V, 240V 50-400Hz.

    • Environment Additional Requirements Available:

      • Outdoor

      • Transformer Oil

    • Miscellaneous Available:

      • Power on/off switch

Specifications are for reference only and are subject to change.
Contact Ross Engineering Corp. for current information.