FIBER OPTIC TRANSMISSION
SYSTEMS
Analog Wideband DC-1MHz
Input Voltage Ranges:
Switch selectable with over 1000 megohm, 30pF
input. 0 to ±1V PK, 0 to ±5V PK,
0 to ±10V PK. Other ranges available.
To 1,000,000V PK with matched Ross wideband voltage divider
Output Voltage
Ranges:
Independent of transmitter
setting. 0 to ±1V PK. 0 to ±5V PK, 0 to ±10V PK.
Max output current
10MA. To ±0.5V PK into 50 ohms. To ±10V PK into 1,000 ohms or higher
such as 1 to 10 megohms, with up to 15ft. coax to 1MHz.
Basic Accuracy:
0.3% DC, 0.5% 1Hz-400Hz, 3% 400Hz-100KHz,
10% 100KHz-1MHz
Transmission
Distance:
1 Kilometer
Signal transmission not affected by shock, vibration or change in
light intensity.
Power
Requirements:
Transmitter
115V or 230V 50/6OHz and/or 12V DC powered, with integral charger or
±15V DC + 5V DC source. Optional remote on/off controlled by fiber optic
cable from receiver. Standard 7AH 12V battery provides 8-15 hours of
operation between charges, longer available. (Additional 12V battery can
be added for longer operation). Also isolated at 115V or 230V 50/60Hz
generator with 150 KV PK isolation or more to power source available for
continuous operation without need for battery, 5V. Or +15V 65MA, -15V
40MA, +5V 130MA, 3.5w DC.
Receiver
115V or 230V 50/60Hz, 5VA,
AC powered and/or 12V DC battery powered or +15V 65MA, -15V 40MA, +5V
130MA DC powered. 3.5 Watts.
|